Sealed pressure sensor pads for wheelchairs, armchairs, sofas and care beds.
The alarm fires on the weight-shift that starts a transfer - not after the seat is already empty.
OEM / ODM for care providers and alarm brands.
HOW IT WORKS
Pre-Exit Detection, Not Post-Exit Alarm
The known weakness of exit alarms is that a pad which only reports an empty seat gives staff no time to reach the resident. Our pads trigger on the load transfer that begins a stand-up attempt.
LOAD-SHIFT TRIGGER
The alarm threshold is set on falling load, not zero load. Leaning forward onto the armrests already crosses it.
ADJUSTABLE DELAY
A 0 - 5 s confirmation window suppresses nuisance alarms from repositioning while keeping the useful head start.
CONTINUITY SUPERVISION
A disconnected or failed pad reports itself. A silent alarm is worse than no alarm at all.
One Platform, Every Seating Surface
Chair pads for wheelchairs, armchairs and sofas; long bed pads for care beds. Identical connector and signal behaviour across the range, so a facility stocks one monitor type.
CHAIR EXIT SENSOR PAD
Sealed wipe-clean vinyl pad for wheelchair seats, armchairs and sofas. Bilingual face print with an orientation arrow so care staff cannot install it upside down.
• 25 x 30 cm active area
• Bilingual EN / ES face print
• Single-key white connector
BED EXIT PAD + MONITOR KIT
Long-format under-sheet pad supplied with the alarm monitor. The printed face carries the four-step setup and a dated replacement reminder field.
• 25 x 90 cm long format
• Upper-body or waistline placement
• Monitor kit included
BUILT FOR VOLUME SUPPLY
Pads are produced in matched batches with consistent trigger threshold, cable length and connector keying, so a facility can swap any pad into any monitor without recalibration.
• Batch-matched trigger threshold
• Custom cable length and connector
• Private-label face printing
• Annual replacement programme support
Four Ways To Raise The Alert
The pad is the sensing layer. Where the alert lands is your decision - local sounder, existing nurse-call wiring, wireless pager or your own gateway and dashboard.

Specification Overview
Baseline configuration shown; size, threshold, cable length, connector and face artwork are customised per project.
| PARAMETER | SPECIFICATION |
| Sensing principle | Sealed resistive pressure switch pad |
| Bed pad size | 25 x 90 cm (custom length available) |
| Trigger threshold | approx. 40 kg default, adjustable on request |
| Pad thickness | < 3 mm sealed vinyl envelope |
| Cleaning | Neutral detergent or alcohol wipe compatible |
| Connector | Keyed two-pin white housing, polarity protected |
| Nurse-call output | Dry contact, normally open or closed |
| Power supply | Monitor DC 5 V adaptor or alkaline cells |
| Operating temperature | -10 C to +50 C |
| Chair pad size | 25 x 30 cm (custom outline available) |
| Floor mat size | 60 x 90 cm optional |
| Alarm delay | 0 - 5 s selectable confirmation window |
| Ingress protection | IP54, wipe-clean surface |
| Cable length | 1.2 m standard, custom on request |
| Monitor sound level | 0 - 95 dB adjustable local sounder |
| Wireless range | Up to 150 m open field, optional pager |
| Low-battery alert | Audible and LED indication |
| Rated pad life | 12 months recommended replacement |
Seated Risk And Bed Risk, One Supplier
Chair exit is the daytime risk; bed exit is the night risk. Facilities buying both from one source get consistent behaviour and a single replacement cycle.
01 WHEELCHAIR & DAY ROOM
A seat pad warns staff the moment a resident starts to push up from the wheelchair, supporting supervision without physical restraint.
• Fits standard seat cushions
• Restraint-free approach
• Monitor clips to frame
02 CARE BED, NIGHT SHIFT
The long bed pad sits under the sheet at waist or upper-body level, giving the night nurse warning before the resident reaches the floor.
• Under-sheet placement
• Two sensitivity positions
• Nurse-call integration
03 HOME CARE & FAMILY
A sofa or armchair pad lets a family carer step into the kitchen without losing awareness of an at-risk parent.
04 REHAB & CLINIC SEATING
Waiting-area and therapy chairs are fitted so unsupervised transfer attempts are flagged before they become incidents.
Sealed, Tested, Batch-Matched
Pads are RF-welded into a fully sealed vinyl envelope, then cycle-tested on a mechanical press before packing. A pad that fails threshold repeatability never leaves the line.
RF EDGE WELDING
Fully sealed vinyl envelope with no stitched seam
THRESHOLD CALIBRATION
Every batch verified against the target trigger load
CYCLE TESTING
Mechanical press validation of repeatability
FINAL CONTINUITY CHECK
Cable, connector and pad tested before packing
Built To Medical Device Standards
Manufactured under a medical-device quality management system with biocompatible skin-contact materials and full substance compliance documentation for the EU and US markets.
ISO 13485:2016
Medical QMS
ISO 10993
Biocompatibility
RoHS / REACH
Substance Compliance
Certification and compliance documentation is issued per project scope and provided during technical review.
For OEM use. End-device certifications such as CE MDR and FDA clearance are held by the customer placing the finished product on the market.
Text marks are factual references only; no third-party accreditation artwork is reproduced.
OEM / ODM
Pad outline, threshold, cable and connector built to your drawing.
PRIVATE LABEL
Your brand, languages and instruction artwork printed on the pad face.
MONITOR PAIRING
Pads matched to your existing monitor or nurse-call interface.
SAMPLE & PILOT
Samples in 7 - 12 days, pilot production in 20 - 25 days.