Sealed pressure sensor pads for wheelchairs, armchairs, sofas and care beds.

The alarm fires on the weight-shift that starts a transfer - not after the seat is already empty.

OEM / ODM for care providers and alarm brands.

Appurtenance:
  • Description
  • PRODUCT RANGE
  • SYSTEM INTEGRATION
  • TECHNICAL DATA
  • WHERE IT IS USED
  • MANUFACTURING
  • QUALITY & COMPLIANCE

HOW IT WORKS

Pre-Exit Detection, Not Post-Exit Alarm

The known weakness of exit alarms is that a pad which only reports an empty seat gives staff no time to reach the resident. Our pads trigger on the load transfer that begins a stand-up attempt.

LOAD-SHIFT TRIGGER

The alarm threshold is set on falling load, not zero load. Leaning forward onto the armrests already crosses it.

ADJUSTABLE DELAY

A 0 - 5 s confirmation window suppresses nuisance alarms from repositioning while keeping the useful head start.

CONTINUITY SUPERVISION

A disconnected or failed pad reports itself. A silent alarm is worse than no alarm at all.

One Platform, Every Seating Surface

Chair pads for wheelchairs, armchairs and sofas; long bed pads for care beds. Identical connector and signal behaviour across the range, so a facility stocks one monitor type.

CHAIR EXIT SENSOR PAD

Sealed wipe-clean vinyl pad for wheelchair seats, armchairs and sofas. Bilingual face print with an orientation arrow so care staff cannot install it upside down.

• 25 x 30 cm active area

• Bilingual EN / ES face print

• Single-key white connector

BED EXIT PAD + MONITOR KIT

Long-format under-sheet pad supplied with the alarm monitor. The printed face carries the four-step setup and a dated replacement reminder field.

• 25 x 90 cm long format

• Upper-body or waistline placement

• Monitor kit included

BUILT FOR VOLUME SUPPLY

Pads are produced in matched batches with consistent trigger threshold, cable length and connector keying, so a facility can swap any pad into any monitor without recalibration.

• Batch-matched trigger threshold

• Custom cable length and connector

• Private-label face printing

• Annual replacement programme support

Four Ways To Raise The Alert

The pad is the sensing layer. Where the alert lands is your decision - local sounder, existing nurse-call wiring, wireless pager or your own gateway and dashboard.

ScreenShot_2026-09-21_131217_902.jpg

Specification Overview

Baseline configuration shown; size, threshold, cable length, connector and face artwork are customised per project.

PARAMETER SPECIFICATION
Sensing principle Sealed resistive pressure switch pad
Bed pad size 25 x 90 cm (custom length available)
Trigger threshold approx. 40 kg default, adjustable on request
Pad thickness < 3 mm sealed vinyl envelope
Cleaning Neutral detergent or alcohol wipe compatible
Connector Keyed two-pin white housing, polarity protected
Nurse-call output Dry contact, normally open or closed
Power supply Monitor DC 5 V adaptor or alkaline cells
Operating temperature -10 C to +50 C
Chair pad size 25 x 30 cm (custom outline available)
Floor mat size 60 x 90 cm optional
Alarm delay 0 - 5 s selectable confirmation window
Ingress protection IP54, wipe-clean surface
Cable length 1.2 m standard, custom on request
Monitor sound level 0 - 95 dB adjustable local sounder
Wireless range Up to 150 m open field, optional pager
Low-battery alert Audible and LED indication
Rated pad life 12 months recommended replacement

Seated Risk And Bed Risk, One Supplier

Chair exit is the daytime risk; bed exit is the night risk. Facilities buying both from one source get consistent behaviour and a single replacement cycle.

01 WHEELCHAIR & DAY ROOM

A seat pad warns staff the moment a resident starts to push up from the wheelchair, supporting supervision without physical restraint.

• Fits standard seat cushions

• Restraint-free approach

• Monitor clips to frame

02 CARE BED, NIGHT SHIFT

The long bed pad sits under the sheet at waist or upper-body level, giving the night nurse warning before the resident reaches the floor.

• Under-sheet placement

• Two sensitivity positions

• Nurse-call integration

03 HOME CARE & FAMILY

A sofa or armchair pad lets a family carer step into the kitchen without losing awareness of an at-risk parent.

04 REHAB & CLINIC SEATING

Waiting-area and therapy chairs are fitted so unsupervised transfer attempts are flagged before they become incidents.

Sealed, Tested, Batch-Matched

Pads are RF-welded into a fully sealed vinyl envelope, then cycle-tested on a mechanical press before packing. A pad that fails threshold repeatability never leaves the line.

RF EDGE WELDING

Fully sealed vinyl envelope with no stitched seam

THRESHOLD CALIBRATION

Every batch verified against the target trigger load

CYCLE TESTING

Mechanical press validation of repeatability

FINAL CONTINUITY CHECK

Cable, connector and pad tested before packing

Built To Medical Device Standards

Manufactured under a medical-device quality management system with biocompatible skin-contact materials and full substance compliance documentation for the EU and US markets.

ISO 13485:2016

Medical QMS

ISO 10993

Biocompatibility

RoHS / REACH

Substance Compliance

Certification and compliance documentation is issued per project scope and provided during technical review.

For OEM use. End-device certifications such as CE MDR and FDA clearance are held by the customer placing the finished product on the market.

Text marks are factual references only; no third-party accreditation artwork is reproduced.

OEM / ODM

Pad outline, threshold, cable and connector built to your drawing.

PRIVATE LABEL

Your brand, languages and instruction artwork printed on the pad face.

MONITOR PAIRING

Pads matched to your existing monitor or nurse-call interface.

SAMPLE & PILOT

Samples in 7 - 12 days, pilot production in 20 - 25 days.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000